  Datasheet File OCR Text:
  emp protection units pcm data lines to 2 mbit/s series/type: B84320Z0010H034 date: january 2004 ? epcos ag 2004. reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without epcos' prior express consent is prohibited. purchase orders are subject to the general conditions for the supply of products and services of the electrical and electronics industry recommended by the zvei (german electrical and electronic manufacturers' associ- ation), unless otherwise agreed.
1) typical test pulse: rise time 10 ns, time to half value 1500 ns, charge voltage min. 50 kv, source impedance 90 w general the emp protection unit is sequenced, i.e. to use simultaneously the benefits of inert-gas-filled surge arresters (extremely high surge capability) and of varistors (fast response). they are isola- ted by a series inductor. the arrester is housed in a plug-in socket, so it can be removed and tested without detaching the lines. note on voltage figures: the maximum voltage on the filter output depends primarily on the rise time until the arrester re- sponds. for this reason the maximum voltage on the filter output is stated in the following table as a function of the rising edge dv/dt of the pulse. technical data rated voltage v r 10 v rated frequency f r 0 ... 2 mbit/s pass bandwidth at z l rated current i r 100 ma referred to +40 c ambient temperature number of lines 10 pairs line impedance z l 124 w maximum dc resistance r max <2.2 w per line permissible ambient temperature t a  25/+40 c climatic category (en 60068-1) 25/085/56  25 c/+85 c/56 days damp heat test approx. weight 300 g nominal dc spark-over voltage v sdcn <800 v nominal surge current 5 ka line/line (8/20 m s) 10 ka pair/case suppression condition i < i r maximum voltage on filter output: at rising edge unsymmetrical symmetrical dv/dt = 0.1 kv/ m s 60 v 8 v dv/dt = 1 kv/ m s 90 v 15 v dv/dt = 1 kv/ns 1) 70 v 40 v emp protection units B84320Z0010H034 pcm data lines to 2 mbit/s 2
circuit diagram (only one of 10 pairs shown) insertion loss a e per pair (typical values at z = 50 w ) asymmetrical measurement circuit to mil-std-220a emp protection units B84320Z0010H034 pcm data lines to 2 mbit/s 3
dimensional drawing side view terminal strip: terminals with cage strain system, suitable for conductors 0.08 ... 2.5 mm 2 front view of protected end installation section and attachment emp protection units B84320Z0010H034 pcm data lines to 2 mbit/s 4


▲Up To Search▲   

 
Price & Availability of B84320Z0010H034

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X